HH Engitech is Approved Fabricator To Manufacture Tank Lorry To Carry Petroleum Products Under “The Petroleum Rule, 2002” By Petroleum And Explosives Safety Organization (PESO), Nag Pur.
We Are Producing These Tanks From Mild Steel, Stainless Steel And Aluminum Material. We Are Producing Both Top Loading And Bottom Loading Tanks For Rigid Vehicles And Semi Trailers.
We Are Supplying Fuel Tanks On Major Truck Chassis Models I.G. TATA, Ashok Leyland, Bharat Benz, Eicher And Mahindra, Oil Tanker Manufacturers in Gujarat.
Oil Tanks Produced By VFPL Are Equipped With All Safety Equipment And Accessories, Which Are Procured From The PESO Approved Vendors. Our Fuel Tanks Come With Stainless Steel Valve Box With Centralized Locking System To Stop Adulteration And Coaming At The Top As A Rollover Protection.
On Request We Provide Tanks With FRP Lining And EP Coating On Inner Side. Foldable Handrail Can Be Provided.
Our Oil Tank Sizes Based On Different Vehicle Capacity Is As Follow:
Vehicle GVW | Tank Size | Compartments |
---|---|---|
16 GVW | 12 kl | 3 Nos. (4 kl Each) or 4 Nos. (3 kl Each) |
25 GVW | 18 kl/ 20 kl | 4 Nos.(4 kl 2 Nos.,5 kl 2 nos.) or (5 kl Each) |
31 GVW | 24 kl | 5 Nos. (4 kl 1 no., 5 kl 4 Nos.) |
37 GVW | 28 kl / 29 kl | 4 Nos. (7 kl each)/ 5 Nos (4 Nos 6 kl ,1 Nos 5 kl) |
40 GVW | 30 kl In Mild Steel | 5 Nos (6 kl Each) |
49 GVW | 35 kl in Mild Steel And 40 kl In Aluminum | 5 Nos. (7 kl each)/ 6 Nos. (4 Nos. 7 kl, 1 Nos 5 kl) |
General Specifications For Top Loading Tanks:
Nozzles | 18″ Manhole In Each compartment with 4″ Fill pipe,1″ Dip Pipe ,P-V Valve And Feasible Vent. |
OPERATING PRESSURE | Atmospheric |
VALVES AND DISCHARGE | 3″ Delivery Line With Emergency Valve Operated By Mechanical Lever From Rear Side On Each Compartment and GUN Metal Valve / Three Piece Ball Valve At Front Delivery Header |
OTHER ACCESSORIES | Fire Extinguishers, Valve Box, Mud guards, SUPD, Catwalk with Hand rail And Ladder |
TESTING | Hydro Test At 0.35 kg/cm2 In Individual Compartment. |
SURFACE PREPARATION | 3-D Pre Treatment Then coated With Protective Layer Of Zinc phosphate. Final Coating of PU paint And Shade As Per User Choice. |
General Specifications For Bottom Loading Tanks:
Nozzles | 20″ Clamped Manhole In Each compartment with Vapour Recovery Line, P-V Valve And Level Sensor |
OPERATING PRESSURE | Atmospheric |
VALVES AND DISCHARGE | 4″ Delivery Line With Emergency Valve pneumatic Operated On Each Compartment |
OTHER ACCESSORIES | Gravity Coupler, Vapour Adopter, Control panel Box Housing With Lock , Valve Box, Fire Extinguishers, Mud Guards, SUPD, Catwalk with Hand Rail And Ladder |
TESTING | Hydro Test At 0.35 kg/cm2 In Individual Compartment. |
SURFACE PREPARATION | 3-D Pre Treatment Then coated With Protective Layer Of Zinc phosphate. Final Coating of PU paint And Shade As Per User Choice. |